Ads-environmental-services IntelliServe 2.8.1 950026A7 Manuel d'utilisateur Page 99

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 290
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 98
Data Presentation 5-25
CONFIDENTIAL Covered by ADS Terms of Use and Confidentiality Agreement in Contract
© 2010 ADS LLC. All Rights Reserved.
Note: These curves are based on only the last seven days of collected
data; therefore, may not be accurate for earlier time periods.
9. From the Depth drop-down list, select the type of depth you want to graph
against velocity. DProcessed is the default and recommended depth entity
for viewing.
Note: Several data entities fall under common root entity types and,
therefore, share common root entity names. To expedite and simplify
the entity selection process, the Available Data Entities table lists
these unique root entity names, in place of the individual entity names,
to collectively represent the corresponding entities sharing the common
root names. Selecting a root entity name causes IntelliServe to plot all
the data available for the entities associated with that root entity type for
the selected monitoring points. For example, consider IntelliServe
supports several pressure depth entities (such as PDEPTH, PDEPTH_1,
and PDEPTH_2) that share the same root name (PDEPTH), but may
have different identifiers (numbers following the root name).
Consequently, the entity available for selection from the Available
Data Entities table under this configuration would be PDEPTH, but
IntelliServe would plot all available PDEPTH, PDEPTH_1, and
PDEPTH_2 data on the scattergraphs.
10. In the Min Value and Max Value fields, modify the default minimum and
maximum values you want to use to plot the selected depth. These fields
both default to 0.
Note: If 0 is in the Max field, the x-axis automatically scales to the
highest depth reading recorded at the monitoring point for the selected
date range or the pipe height of the location, whichever is greater.
11. Select the velocity type you want to graph against the selected depth from
the Velocity drop-down list. VProcessed is the default velocity entity and
the recommended velocity entity for viewing.
12. In the Min Value and Max Value fields, modify the default minimum and
maximum values you want to use to plot the selected velocity-to-depth
relationship.
Note: Entering 0 in the Max field auto-scales the y-axis to the highest
velocity reading recorded at the monitoring point for the selected date
range.
Vue de la page 98