© 2009 ADS LLC. All Rights Reserved.
QR 775023 A0
The ADS Mikron is a high performance, simple-to-use leak
locator. The design is based upon an advanced sensor
and incorporates low-noise processing electronics to give
excellent acoustic performance over a wide frequency
range. Mikron incorporates a Minimum Noise Level
measurement system.
QUICK REFERENCE GUIDE
Operation of the ADS Mikron Leak Locator
Mikron
Connectors
Plug the sensor into the top right-side socket of the
amplier. The sensor must only be connected or
disconnected whilst the amplier is turned o. This socket
is also used for the battery charging.
The left-side socket is used to connect the headphone.
Switch-on and O
To turn the amplier on, press any key until it turns on. (The sensor and headphones must be connected before the amplier is
switched on).
To turn the unit o, press the ‘Increase’ and ’Decrease’ buttons together. The amplier will switch o automatically if no button is
pressed for 5 minutes.
Control Buttons
ADS Mikron Hand-held
Leak Locator.
ADS Mikron with
Ground Microphone.
Button Function
Press-to-listen
When pressed the current minimum noise level is shown in the right
(largest) box and sound is available in the headphones. When released
the minimum value in the right box is held in memory.
Decrease
This button is used to decrease the volume in the headphones, or adjust
the screen contrast in screen contrast mode.
Increase
This button is used to increase the volume in the headphones, or adjust
the screen contrast in screen contrast mode.
Store
When pressed and released, the current value of the minimum sound
level (shown in the right hand box) will be stored in the middle box and
the contents of the middle box moved to the left box. The contents of the
left box are discarded. This feature allows the last 3 saved values to be
shown on the screen. Holding the store button for about 3 seconds will
delete the displayed data in the boxes.
Filters
When pressed and released, the filter selection will cycle through the
options. When a new filter is selected the amplifier takes a few seconds to
stabilize. If the Press-to-listen button is pressed at this time the sound
level figure will flash to indicate it is unreliable.